Standard Features:
Motor:
Resilient mount continuous-duty,
high-starting torque motor with instant reverse and overload
protection. Available in 1/2 H.P. (373W); single phase
capacitor start motors. Removable without affecting limit
switch settings.
Wiring Type:
All lift master garage door openers are factory preset to C2
wiring providing momentary contact to open and stop, with
constant contact to close. Momentary contact to close (B2
wiring) can be easily set. The operator is pre-wired to
accept a sensing device, photoelectric control, radio
controls and most types of access control equipment.
Maintenance Alert
System: This important
feature provides an accurate method for tracking door use
and establishing safe and effective maintenance programs for
the door and operator. The Maintenance Alert System features
an internal programmable cycle timer that actually counts
each time the door cycles. This system is easily preset by
the installer for the particular door and application. Once
the preset number is reached, an indicator light on the
3-button station flashes to signal that it is time for
routine door and operator maintenance.
Programmable
Mid-Stop: A standard
feature on the Logic Control Board (L).
Maximum Run Timer:
Protects against damage to the door and
lift master garage door opener .
Auxiliary Reversal
System: If a closing door
strikes an obstruction, the system will detect the slip of
the clutch and reverse the door to the full open position.
This system is not a substitute for a safety sensing device
such as a photo cell or reversing edge.
Delay-on-Reverse
Circuit: A standard
feature on the Logic Control Board (L).
Low Profile Design:
Low profile design can be ceiling mounted
for low headroom applications.
Quiet Operation:
A quality resilient mount motor, nylon
inserts on trolley assembly and nylon quiet gliding chain
guides on rail spacers provide quiet, lift master garage
door opener smooth operation.
Rail Assembly:
High strength dual L-rail track and
quick-mount header bracket which provides fast, swing-up
installation.
Control Circuit:
5VDC NEC class 2.
Drive Reduction:
First stage heavy-duty 4L V-belt; second
and third stages #41 chain; output on trolley #48 chain.
Auto-Reconnect
Trolley Assembly:
Spring-loaded trolley features nylon inserts for quiet
operation and auto-reconnect feature eliminating the need to
manually reattach the door arm to the trolley after
emergency disconnect.
Pushbutton Station:
3-buttons station for OPEN/CLOSE/STOP
functions is standard for all operators. Controls with one,
two and three buttons are available.
Construction:
NEMA 1 type electrical box, heavy-duty
11-gauge painted steel frame, all reduction sprockets
drilled and pinned to shafts.
Bearings:
Industrial ball bearings on the output
shaft; heavy-duty, oil filled on reduction shafts.
External Radio
Control Terminal: External
terminals provide quick, convenient connections for
universal radio controls.
Friction Clutch:
Adjustable friction clutch helps protect
against damage to the door and operator should the door meet
an obstruction.
Control Accessories
and Options:
Sensing Edge:
(Recommended) Designed to sense an
obstruction and signal door operator to stop or reverse as
desired. Either an electric or pneumatic sensing device can
be added to bottom edge of door.
Radio Control:
Portable transmitter signals operator to
open and/or close door.
Treadle:
Signals door operator to open and/or close
when vehicle depresses treadle.
Available Plug-In
Option Boards for the Solid State Logic Control Board (L):
Commercial Protector
SystemTM II:
(Recommended) Features our powerful photo
sensors to provide a UL approved self-monitoring operator
for commercial door applications. 4-wire or 2-wire
"fail-safe" edges may be used. Board also contains a
Timer-to-Close function.
Timer-to-Close
Option: Part of the CPS II
board. It provides the ability to close the door at a
programmable time from 5 seconds up to 1 hour. Combined with
the CPS II board for the convenience of a timer and the
safety necessary to protect an auto closing lift master
garage door opener .
Auxiliary Contact
Board Option: Features
both normally-open and normally-closed contacts that actuate
when unit is powered down. Can be used to signal security
systems, operate heaters, warning devices or other ancillary
devices (5V to 240V).
Warning Signal
Option Board: Provides
apartment warn |